思热99re视热频这里只精品-精品成在人线av无码免费看-成年女人毛片免费视频-亚洲成年看片在线观看-亚洲国产精品无码久久久高潮

Location: Home >>News >>Company News

Transmission line wire fittings online temperature measurement device, power wise patrol "temperature guard"

Author: Click:236 Time:2024-11-12

With the development of the power system, the maintenance of power equipment is becoming more and more heavy, conductors and conductor fittings as an

With the development of the power system, the maintenance of power equipment is becoming more and more heavy, conductors and conductor fittings as an important part of the transmission line, its temperature monitoring is important for the prevention of faults and to protect the power supply. In the operation process, due to the current through the wire will produce Joule heat, so that the temperature of the wire rises. When the temperature of the conductor exceeds its permissible temperature, the mechanical strength of the conductor decreases, which may lead to serious accidents such as conductor strand breakage and wire breakage, affecting the continuity and stability of power transmission. For example, in hot weather or under high load operation, the conductor heat dissipation is difficult and the temperature is easy to rise.




Regular patrol temperature measurement, special patrol temperature measurement and other methods can not reflect the temperature rise of the line in a timely manner, in the high temperature environment or line overload condition, still regularly occurring line overheating caused by power accidents.


Transmission line wire fittings online temperature measurement device composition

The Transmission Line Online temperature measurement device for conductor fittingsDX-WPS100-CW consists of two major parts: monitoring terminal and background software. The monitoring terminal includes a collection unit, monitoring sub-station, server and solar panel, in which the collection unit is installed on the tension-resistant wire clamps and wires, and the monitoring sub-station is deployed on the power tower, which is responsible for receiving the data from each collection unit and sending the collected data to the remote server through wireless network.

The background has the functions of data storage, historical data query, report generation, curve drawing, etc., and can analyze the trend of the wire temperature status.


Principle of operation and applications

Transmission line wire fixture on-line temperature measurement device< Adopting the combination of wire temperature measurement and clamp temperature measurement, a wire temperature sensor is installed on the wire under test, and 1/2/4 clamp temperature sensors are installed at the clamps corresponding to the wire, so that the temperature data of the wire and fixture are collected in real time by the clamp temperature sensors and passed through the 4G/5G/OPG/HYDROBONT temperature sensor, which can be used to measure the temperature of the wire. 4G/5G/OPGW fiber optic network will monitor the data real-time transmission to the monitoring center, data over the limit of the automatic alarm. When the collection terminal to judge the wire clip temperature and adjacent wire temperature difference reaches the following defects will change the corresponding sensor collection, upload frequency.

The application of this device can make up for the shortcomings of manual inspection, reduce the cost of manual maintenance, realize the sign type alarm, and nip accidents in the bud.


Technical characteristics

1、Industrial-class products: the device adopts double-layer stainless steel waterproof shell, suitable for a variety of harsh climatic environments;

2, high-precision sensors: data acquisition unit using high-precision wire clip temperature measurement sensor, measurement, stable and reliable, does not affect the normal operation of the line;

3, flexible communication mode: support 4G/5G/OPGW fiber optic and other communication networks to adapt to different field environments, and communication with the master station can be a dedicated VPN channel;

4, power management features: dynamic power management strategy to meet the requirements of power saving, support for battery overcharge, overdischarge, overcurrent and other protection functions.

Through real-time monitoring of the temperature of the conductor, once the temperature is found to be abnormally high, the electrician can take timely measures, such as adjusting the load, strengthening heat dissipation, etc., to prevent the occurrence of overheating faults and to ensure the safe operation of transmission lines.



Related recommendations

The online monitoring, distributed fault location and cable online monitoring equipment for power transmission and distribution lines launched by SHENZHEN DINSEE SMART TECHNOLOGY CO.,LTD. has been widely used in Southern Power Grid and State Grid, and has achieved good results.

Record No.: Yue ICP Bei 2022070794-1 | Website Map XML Map

主站蜘蛛池模板: 夜夜春亚洲嫩草影院| 亚洲精品中文字幕无码蜜桃| 无码精品a∨动漫在线观看| 中文字幕乱码人妻无码久久| 2021久久精品国产99国产精品| 亚洲国产初高中生女av| 色欲久久久中文字幕综合网| 男女啪啪永久免费网站| 狠狠躁夜夜躁人人爽天天古典| 日韩精品无码专区免费播放| 亚洲日韩欧美内射姐弟| 丰满少妇被粗大的猛烈进出视频| av天堂久久天堂av| 久久精品国产99久久美女| 日韩av无码中文无码不卡电影| 四川丰满妇女毛片四川话| 精品无人区无码乱码大片国产| 人人澡人人透人人爽| 精品乱码无人区一区二区| 国产综合久久99久久| 亚洲人成色4444在线观看| 伊人久久精品无码麻豆一区| 亚洲精品国产首次亮相| 国产精品无码一区二区三区在| 日本一卡2卡3卡四卡精品网站| 国产精品亚洲一区二区| 免费人成在线观看| 亚洲精品成人av观看| 欧美亚洲国产精品久久蜜芽| 国产精品成人永久在线四虎| 精品人妻少妇一区二区三区不卡 | 亚洲香蕉成人av网站在线观看| 18禁止午夜福利体验区| 午夜精品国产精品大乳美女| 欧美日韩精品一区二区性色a+v| 伊人久久五月丁香综合中文亚洲| 欧美性白人极品1819hd| 精品第一国产综合精品蜜芽| 亚洲欧洲日产国码韩国| 海角社区在线视频播放观看| 国产精品人成电影在线观看|