成 人 网 站 在 线 免费 观 看-精品国内自产拍在线播放观看-亚洲精品视频播放-色噜噜狠狠综曰曰曰-久久视频网-亚洲国产精品成人精品无码区-风流还珠之乱淫h文-可以直接免费观看的av网站-97久久综合-国产激情91久久精品导航-日韩在线观看视频网站-日韩欧美在线观看视频-精品欧美一区二区精品久久久-第一136av福利视频导航-97精品国产一区二区三区

Location: Home >>News >>Company News

Cable sheath ground loop current online monitoring device application principle and installation considerations

Author: Click:625 Time:2024-02-27

The problem of cable sheath ring current has always been a key concern for cable operation. The size of the ring current with the cable length and the

The problem of cable sheath ring current has always been a key concern for cable operation. The size of the ring current with the cable length and the current flowing through the cable, long-term sheath ring current will lead to accelerated aging of the cable insulation, affecting the service life of the cable. Under certain circumstances, the cable sheath ring current can even reach 50% ~ 95% of the cable conductor load current value, seriously endangering the cable equipment and personal safety.



How to detect cable loop current abnormality in advance to prevent the occurrence of cable grounding and larger faults? The following will introduce the application of one of our cable sheath grounding loop current online monitoring device:



Application Principle

Cable sheath ground loop current online monitoring device DX-DLS100-HL collects cable loop current data through the current transformer installed on the metal sheath lead line, at the same time, one end of the voltage collection device is directly connected to the metal sheath, and the other end is connected to the data collector, so that it can get the voltage value of the metal sheath. Through the wireless network, the data will be sent to the monitoring center for storing, analyzing and displaying, the data abnormality will be alarmed automatically, and the specific location of the abnormality point can also be displayed on the electronic map of the monitoring center.




Installation Precautions

1, you need to plan in advance the installation location, generally installed in the high fault section, such as cable terminals, joints, etc., conditions allow, try to install multiple sensors in different nodes to carry out more monitoring.


2, confirm the wiring of the sensor to ensure that the monitoring equipment and the normal connection of the cable. Installation of monitoring equipment as close as possible to the sensor, but also take into account the equipment lightning and protection issues.


3, the network connection, ensure smooth communication, facilitate the monitoring system can be normal data transmission and processing.


Related recommendations

The online monitoring, distributed fault location and cable online monitoring equipment for power transmission and distribution lines launched by DINSEE SMART TECHNOLOGY CO.,LTD. has been widely used in Southern Power Grid and State Grid, and has achieved good results.

Record No.: Yue ICP Bei 2022070794-1 | Website Map XML Map